Vapor Generation Sources

Enter production and operational parameters

Tank Battery Parameters

Atmospheric tanks: 2-8 oz
Typically matches sales line or fuel gas pressure

VRU Sizing Results

Enter parameters and click Calculate

Formula Reference

Flash Gas Calculation (Vasquez-Beggs)

Flash Ratio = (P1/P2)^(1/n) - 1 Simplified Flash Gas Rate: Qflash (MCFD) = Oil_Rate * GOR * Flash_Factor / 1000 Flash Factor = 1 - (Ptank/Psep)^0.5 Where: Ptank = Tank pressure (psia) Psep = Separator pressure (psia)

Working Losses (EPA AP-42)

Working Loss: Lw = 0.0010 * Mv * Pva * D * H * N * Kn * Kp Where: Mv = Molecular weight of vapor Pva = Vapor pressure at temperature D = Tank diameter (ft) H = Outage height (ft) N = Number of turnovers per year Kn = Turnover factor Kp = Product factor

Compressor Sizing

Compression Ratio: r = (P_discharge + 14.7) / (P_suction + 14.7) Adiabatic HP (per stage): HP = (Q * P1 * k) / (229.17 * (k-1)) * [(r^((k-1)/k)) - 1] Where: Q = Flow rate (MCFD) P1 = Suction pressure (psia) k = Specific heat ratio (~1.26 for hydrocarbon gas) r = Compression ratio